{"id":80134,"date":"2026-01-19T14:27:04","date_gmt":"2026-01-19T22:27:04","guid":{"rendered":"https:\/\/lagunawoodsvillage.com\/?post_type=document&#038;p=80134"},"modified":"2026-03-24T11:53:35","modified_gmt":"2026-03-24T18:53:35","slug":"third-standard-11a-materials-registration-form","status":"publish","type":"document","link":"https:\/\/lagunawoodsvillage.com\/zh\/document\/third-standard-11a-materials-registration-form\/","title":{"rendered":"Third Standard 11A Materials Registration Form"},"content":{"rendered":"<p>PA<\/p>\n<p>\u62c9\u53e4\u7eb3\u4f0d\u5179\u6751<\/p>\n<p>New Flooring Materials Registration Form<\/p>\n<p>The undersigned member of Laguna Woods Village hereby submits this completed form to register new flooring<\/p>\n<p>alterations as described below.<\/p>\n<p>By submitting this form, the member acknowledges and agrees to comply with the applicable mutual flooring<\/p>\n<p>standards:<\/p>\n<p>.<\/p>\n<p>United Laguna Woods Mutual: Standard 9 \u2014 Interior Flooring for Second Floor Manors<\/p>\n<p>.<\/p>\n<p>Third Laguna Hills Mutual: Standard 11A \u2014 Interior Flooring for Second and\/or Third Floor Manors<\/p>\n<p>The member further understands and agrees to abide by the interior flooring grievance procedure, should that<\/p>\n<p>process become necessa ry.<\/p>\n<p>Upon submission, Manor Alterations will email a confirmation, which will include an assigned receipt number.<\/p>\n<p>Members should retain this receipt number and the completed form for their records. If a confirmation email is<\/p>\n<p>not received, please contact Manor Alterations at alterations@vmsinc.org or 949-597-4616.<\/p>\n<p>The submitted form will be kept on file with Manor Alterations and referenced only if required as part of the<\/p>\n<p>interior flooring grievance procedure.<\/p>\n<p>Click here to visit the Manor Alterations webpage and view Standards 9 and 11A.<\/p>\n<p>Underlayment specifications (attachments OK): (Required)<\/p>\n<p>Delta AIC<\/p>\n<p>(Required)<\/p>\n<p>Finish flooring specifications (attachments OK): (Required)<\/p>\n<p>Delta AlIC<\/p>\n<p>(*Requested)<\/p>\n<p>Flooring installation contractor:<\/p>\n<p>(Required)<\/p>\n<p>Installation date:<\/p>\n<p>(Required)<\/p>\n<p>*If and when tested, the member remains responsible for meeting the sound testing requirements as established by this standard.<\/p>\n<p>Attention: Original flooring materials are required to be presumed asbestos containing material (PACM) as per 29CFR 1910.1001(j)(2)(i)<\/p>\n<p>Occupational Safety and Health Administration (OSHA). It is the members responsibility to check with the City of Laguna Woods Permits<\/p>\n<p>Office (949-639-0500) and their contractor to determine what steps are required to test or handle the original flooring if it is still present.<br \/>\nPA<\/p>\n<p>\u62c9\u53e4\u7eb3\u4f0d\u5179\u6751<\/p>\n<p>1. Receipt of Standards and Cross-Section Requirement<\/p>\n<p>3. Assumption of Risk and Responsibility for Alterations<\/p>\n<p>As part of the mutual\u2019s alteration process, the member must receive a<\/p>\n<p>I understand and agree that | am solely responsible for all risks<\/p>\n<p>copy of the applicable mutual standard and the floor\/ceiling assembly<\/p>\n<p>associated with any alteration(s) or improvement(s), including, but<\/p>\n<p>cross section handout related to the requested mutual consent.<\/p>\n<p>not limited to, the cost of removing, altering, protecting or replacing<\/p>\n<p>To ensure compliance, the member&#8217;s signature below confirms<\/p>\n<p>such work if necessary to accommodate corporation business.<\/p>\n<p>receipt of these documents. A mutual consent will not be issued<\/p>\n<p>without this required acknowledgment.<\/p>\n<p>4. Liability for Damages and Remediation Costs<\/p>\n<p>| understand and agree that | am responsible for, and will bear all<\/p>\n<p>2. Acknowledgment of Responsibility and Potential Penalties<\/p>\n<p>costs related to, any alteration(s) or improvement(s), including<\/p>\n<p>| understand that failure by my contractor and\/or myself to comply<\/p>\n<p>expenses for remediation, clean-up or repair of mutual-owned<\/p>\n<p>with mutual rules and regulations will result in nonconformance.<\/p>\n<p>or mutual-controlled property resulting from or caused by such<\/p>\n<p>| acknowledge that such non-compliance may subject me to<\/p>\n<p>work or its installation.<\/p>\n<p>disciplinary action, including potential fines, in accordance with<\/p>\n<p>the mutual\u2019s schedule of monetary penalties.<\/p>\n<p>| understand that | am responsible for the actions of my contractor(s), and | understand that | am responsible for<\/p>\n<p>any damages claims, fines or violations that result from the actions or inactions of my contractors(s) or guest(s).<\/p>\n<p>Full Name (Required)<\/p>\n<p>\u7b2c\u4e00\u7684<\/p>\n<p>\u6700\u540e\u7684<\/p>\n<p>Manor Number (Required)<\/p>\n<p>Manor Unit (Required)<\/p>\n<p>Resident ID Number (Required)<\/p>\n<p>Email (Required)<\/p>\n<p>Phone Number (Required)<\/p>\n<p>MEMEBER: IMPORTANT &#8211; PLEASE READ CAREFULLY<br \/>\nFLOOR \/ CEILING ASSEMBLY CROSS SECTION<\/p>\n<p>Materials\/Components Breakdown<\/p>\n<p>Conditions suggested to achieve an OVERALL AIC rating of 57dB<\/p>\n<p>MEMBER RESPONSIBLITYY:<\/p>\n<p>FINISH FLOOR NEW: Delta A lIC ratings here are<\/p>\n<p>\u2014<\/p>\n<p>suggested only. Member remains responsible<\/p>\n<p>fo meet the sound ratings of this Standard if or<\/p>\n<p>when testing is required.<\/p>\n<p>Suggested Delta A IIC 12dB or higher<\/p>\n<p>OVERALL<\/p>\n<p>ASSEMBLY<\/p>\n<p>Must Meet<\/p>\n<p>MEMBER RESPONSIBILITY:<\/p>\n<p>An AlIC<\/p>\n<p>SUBFLOOR \/ UNDERLAYMENT NEW \u2014<\/p>\n<p>Rating of<\/p>\n<p>Required Delta AlIC of 20dB or higher<\/p>\n<p>57dB<\/p>\n<p>EE,<\/p>\n<p>SEER<\/p>\n<p>hid<\/p>\n<p>2&#8243; -2 1\/2&#8243; Light weight concrete<\/p>\n<p>FLOOR \/<\/p>\n<p>CEILNG<\/p>\n<p>ASSEMBLY \u2014<\/p>\n<p>15# felt or 2 mil visqueen<\/p>\n<p>Existing and<\/p>\n<p>Typical;<\/p>\n<p>1\/2&#8243; layer of plywood<\/p>\n<p>ASSUMED<\/p>\n<p>AlIC rating<\/p>\n<p>\u2014<\/p>\n<p>of 35-40dB;<\/p>\n<p>2 x 10 Floor Joists at 12&#8243; or 16&#8243; on<\/p>\n<p>if required,<\/p>\n<p>center<\/p>\n<p>verification<\/p>\n<p>by field test<\/p>\n<p>\u2014\u2014<\/p>\n<p>\u2014<\/p>\n<p>_\u2014\u2014<\/p>\n<p>Insulation<\/p>\n<p>is needed.<\/p>\n<p>\u2014\u2014\u2014\u2014\u2014<\/p>\n<p>\u2014_\u2014<\/p>\n<p>\u2014<\/p>\n<p>FINISHED CEILING: 1\/2&#8243; -7\/8&#8243;<\/p>\n<p>drywall \/ plaster<\/p>\n<p>Summary Example Only:<\/p>\n<p>1<\/p>\n<p>MEMBER RESPONSIBILITY: Finish Flooring \u2014 new component. Factored<\/p>\n<p>together with existing floor\/ceiling assembly. The member remains<\/p>\n<p>responsible to meet the overall sound ratings<\/p>\n<p>of this Standard. Suggested delta AlIC:<\/p>\n<p>Range:<\/p>\n<p>12dB<\/p>\n<p>2dB<\/p>\n<p>MEMBER RESPONSIBILITY: NEW Subfloor underlayment \u2014<\/p>\n<p>All subfloor underlayments are required to meet a<\/p>\n<p>sound rating of delta AlIC of 20 dB or higher.<\/p>\n<p>Note: Actual field conditions may vary.<\/p>\n<p>Range:<\/p>\n<p>10dB<\/p>\n<p>15dB<\/p>\n<p>EXISTING: Floor \/ Ceiling Assembly = estimate only<\/p>\n<p>based on prior testing. Field testing required;<\/p>\n<p>(member responsibility) for actual AlIC rating<\/p>\n<p>Example Only Range:<\/p>\n<p>35dB<\/p>\n<p>40dB<\/p>\n<p>AlIC Totals<\/p>\n<p>57dB<\/p>\n<p>57dB<\/p>\n<p>\u7b14\u8bb0\uff1a<\/p>\n<p>While carpet and pad over new subfloor will generally meet the Standard\u2019s sound rating<\/p>\n<p>requirements, other flooring products are allowed, provided &#8211; if and when tested &#8211; they also<\/p>\n<p>meet the Standard\u2019s sound rating requirements. This remains the members responsibility.<\/p>\n<p>revised: 1-22-2026<\/p>","protected":false},"author":28,"featured_media":0,"template":"","document_category":[1127],"document_type":[53],"class_list":["post-80134","document","type-document","status-publish","hentry","document_category-manor-alterations","document_type-other"],"acf":{"document":84239,"resolutions":null,"legacy_id":"","pdf_extracted_text":""},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.1.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Third Standard 11A Materials Registration Form | Laguna Woods Village<\/title>\n<meta name=\"robots\" content=\"noindex, follow\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Third Standard 11A Materials Registration Form | Laguna Woods Village\" \/>\n<meta property=\"og:description\" content=\"PA Laguna Woods Village New Flooring Materials Registration Form The undersigned member of Laguna Woods Village hereby submits this completed form to register new flooring alterations as described below. By submitting this form, the member acknowledges and agrees to comply with the applicable mutual flooring standards: . United Laguna Woods Mutual: Standard 9 \u2014 Interior [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/lagunawoodsvillage.com\/zh\/document\/third-standard-11a-materials-registration-form\/\" \/>\n<meta property=\"og:site_name\" content=\"Laguna Woods Village\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/LagunaWoodsVillage\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-24T18:53:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/attachments.lagunawoodsvillage.com\/wp-content\/uploads\/2024\/06\/26175354\/2c5053c2b1c58b7e3c7faae3205bbe3e.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"614\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/lagunawoodsvillage.com\/document\/third-standard-11a-materials-registration-form\/\",\"url\":\"https:\/\/lagunawoodsvillage.com\/document\/third-standard-11a-materials-registration-form\/\",\"name\":\"Third Standard 11A Materials Registration Form | Laguna Woods Village\",\"isPartOf\":{\"@id\":\"https:\/\/lagunawoodsvillage.com\/#website\"},\"datePublished\":\"2026-01-19T22:27:04+00:00\",\"dateModified\":\"2026-03-24T18:53:35+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/lagunawoodsvillage.com\/document\/third-standard-11a-materials-registration-form\/#breadcrumb\"},\"inLanguage\":\"zh-CN\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/lagunawoodsvillage.com\/document\/third-standard-11a-materials-registration-form\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/lagunawoodsvillage.com\/document\/third-standard-11a-materials-registration-form\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/lagunawoodsvillage.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Third Standard 11A Materials Registration Form\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/lagunawoodsvillage.com\/#website\",\"url\":\"https:\/\/lagunawoodsvillage.com\/\",\"name\":\"Laguna Woods Village\",\"description\":\"Private Retirement Community in Orange County, California\",\"publisher\":{\"@id\":\"https:\/\/lagunawoodsvillage.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/lagunawoodsvillage.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-CN\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/lagunawoodsvillage.com\/#organization\",\"name\":\"Laguna Woods Village\",\"url\":\"https:\/\/lagunawoodsvillage.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-CN\",\"@id\":\"https:\/\/lagunawoodsvillage.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/attachments.lagunawoodsvillage.com\/wp-content\/uploads\/2024\/06\/21232229\/laguna-woods-logo.jpg\",\"contentUrl\":\"https:\/\/attachments.lagunawoodsvillage.com\/wp-content\/uploads\/2024\/06\/21232229\/laguna-woods-logo.jpg\",\"width\":502,\"height\":266,\"caption\":\"Laguna Woods Village\"},\"image\":{\"@id\":\"https:\/\/lagunawoodsvillage.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/LagunaWoodsVillage\/\",\"https:\/\/www.youtube.com\/user\/LagunaWoodsVlg\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Third Standard 11A Materials Registration Form | Laguna Woods Village","robots":{"index":"noindex","follow":"follow"},"og_locale":"zh_CN","og_type":"article","og_title":"Third Standard 11A Materials Registration Form | Laguna Woods Village","og_description":"PA Laguna Woods Village New Flooring Materials Registration Form The undersigned member of Laguna Woods Village hereby submits this completed form to register new flooring alterations as described below. By submitting this form, the member acknowledges and agrees to comply with the applicable mutual flooring standards: . United Laguna Woods Mutual: Standard 9 \u2014 Interior [&hellip;]","og_url":"https:\/\/lagunawoodsvillage.com\/zh\/document\/third-standard-11a-materials-registration-form\/","og_site_name":"Laguna Woods Village","article_publisher":"https:\/\/www.facebook.com\/LagunaWoodsVillage\/","article_modified_time":"2026-03-24T18:53:35+00:00","og_image":[{"width":1024,"height":614,"url":"https:\/\/attachments.lagunawoodsvillage.com\/wp-content\/uploads\/2024\/06\/26175354\/2c5053c2b1c58b7e3c7faae3205bbe3e.jpeg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/lagunawoodsvillage.com\/document\/third-standard-11a-materials-registration-form\/","url":"https:\/\/lagunawoodsvillage.com\/document\/third-standard-11a-materials-registration-form\/","name":"Third Standard 11A Materials Registration Form | Laguna Woods Village","isPartOf":{"@id":"https:\/\/lagunawoodsvillage.com\/#website"},"datePublished":"2026-01-19T22:27:04+00:00","dateModified":"2026-03-24T18:53:35+00:00","breadcrumb":{"@id":"https:\/\/lagunawoodsvillage.com\/document\/third-standard-11a-materials-registration-form\/#breadcrumb"},"inLanguage":"zh-CN","potentialAction":[{"@type":"ReadAction","target":["https:\/\/lagunawoodsvillage.com\/document\/third-standard-11a-materials-registration-form\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/lagunawoodsvillage.com\/document\/third-standard-11a-materials-registration-form\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/lagunawoodsvillage.com\/"},{"@type":"ListItem","position":2,"name":"Third Standard 11A Materials Registration Form"}]},{"@type":"WebSite","@id":"https:\/\/lagunawoodsvillage.com\/#website","url":"https:\/\/lagunawoodsvillage.com\/","name":"\u62c9\u53e4\u7eb3\u4f0d\u5179\u6751","description":"\u52a0\u5dde\u5965\u5170\u6cbb\u53bf\u79c1\u4eba\u9000\u4f11\u793e\u533a","publisher":{"@id":"https:\/\/lagunawoodsvillage.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/lagunawoodsvillage.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-CN"},{"@type":"Organization","@id":"https:\/\/lagunawoodsvillage.com\/#organization","name":"\u62c9\u53e4\u7eb3\u4f0d\u5179\u6751","url":"https:\/\/lagunawoodsvillage.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-CN","@id":"https:\/\/lagunawoodsvillage.com\/#\/schema\/logo\/image\/","url":"https:\/\/attachments.lagunawoodsvillage.com\/wp-content\/uploads\/2024\/06\/21232229\/laguna-woods-logo.jpg","contentUrl":"https:\/\/attachments.lagunawoodsvillage.com\/wp-content\/uploads\/2024\/06\/21232229\/laguna-woods-logo.jpg","width":502,"height":266,"caption":"Laguna Woods Village"},"image":{"@id":"https:\/\/lagunawoodsvillage.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/LagunaWoodsVillage\/","https:\/\/www.youtube.com\/user\/LagunaWoodsVlg"]}]}},"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/lagunawoodsvillage.com\/zh\/wp-json\/wp\/v2\/document\/80134","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lagunawoodsvillage.com\/zh\/wp-json\/wp\/v2\/document"}],"about":[{"href":"https:\/\/lagunawoodsvillage.com\/zh\/wp-json\/wp\/v2\/types\/document"}],"author":[{"embeddable":true,"href":"https:\/\/lagunawoodsvillage.com\/zh\/wp-json\/wp\/v2\/users\/28"}],"version-history":[{"count":7,"href":"https:\/\/lagunawoodsvillage.com\/zh\/wp-json\/wp\/v2\/document\/80134\/revisions"}],"predecessor-version":[{"id":84241,"href":"https:\/\/lagunawoodsvillage.com\/zh\/wp-json\/wp\/v2\/document\/80134\/revisions\/84241"}],"wp:attachment":[{"href":"https:\/\/lagunawoodsvillage.com\/zh\/wp-json\/wp\/v2\/media?parent=80134"}],"wp:term":[{"taxonomy":"document_category","embeddable":true,"href":"https:\/\/lagunawoodsvillage.com\/zh\/wp-json\/wp\/v2\/document_category?post=80134"},{"taxonomy":"document_type","embeddable":true,"href":"https:\/\/lagunawoodsvillage.com\/zh\/wp-json\/wp\/v2\/document_type?post=80134"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}